Sign In | Join Free | My disqueenfrance.com |
|
MOQ : 100
Payment Terms : T/T
Delivery Time : 1-12 weeks
Packaging Details : Original packing
Rated voltage (A) : 4000V
Measuring range : 0~±6000V
working principle : Magnetic balance
Power supply voltage (V) : ±15 × (1±5%)V
Rated measurement output : 25mA
Basic error : ≦±0.7 %
Linearity error : ≦0.2%
Zero output error (+25 ℃ ) : ≦±0.2mA
NV100-4000V/SP7 voltage sensor
NV100-4000V/SP7 rail voltage sensor model specifications and technical parameters | |
Rated voltage (A) | 4000V |
Product number | NV100-4000V/SP7 |
Measuring range | 0~±6000V |
working principle | Magnetic balance |
Power supply voltage (V) | ± 15 × (1 ± 5%) V |
Rated measurement output | 25mA |
Basic error | ≦±0.7 % |
Linearity error | ≦0.2% |
Zero output error (+25 ℃ ) | ≦ ± 0.2mA |
Response time | ≦200us |
Withstand voltage | 12kV/50Hz/2min |
Operating temperature | -40℃-+70℃ |
![]() |
12kV 4000VA Magnetic Balance Voltage Transducers Images |